Home Tags Grounding

Tag: grounding

Do We Need a Grounded Conductor at that Switch Location or...

Have you ever bought a shirt or sweater only to have second thoughts about the necessity of that purchase before you get the item...

Do you know what ground potential rise is? It’s really important.

Ground potential rise events First of all, ground potential rise is a very important and very dangerous event. The grounding engineer will be required to...

Journey to the Future of 260-year-old Lightning Rod: Where lightning protection...

In most countries around the world, we see that the banknote of the highest denomination bears the face of the most respected figure in the country’s history. In the United States of America, that person is Benjamin Franklin whose face dons the famous $100 bill. This article focuses on the Franklin lightning rod, arguably one of Benjamin Franklin’s greatest achievements, through the scientific and engineering perspective in search of the future of lightning protection technology in the rapidly changing world.

Grounding and Bonding

In this article, we will discuss the fundamentals of bonding and grounding. To start, we should get an understanding of the difference between bonding...

What Is Earthing & Why and How Do We Connect to...

The thin layer of material which covers our planet—rock, clay, chalk or whatever—is what we in the world of electricity refer to as earth. So, why do we need to connect anything to it? After all, it is not as if earth is a good conductor. It might be wise at this stage to investigate potential difference (PD). A PD is exactly what it says it is: a difference in potential (volts). In this way, two conductors having PDs of, say, 20 and 26 V have a PD between them of 26 and 20 V. The original PDs (i.e., 20 and 26 V) are the PDs between 20 V and 0 V and 26 V and 0 V.

Medium Voltage Earthing Systems – Arrangements and Comparison

Neutral point connection method First, let’s define the different medium voltage earthing systems and then compare the advantages and disadvantages of each one. Earthing systems...

Bonding and Grounding PV Systems

The grounding of electrical circuits and systems and the bonding of conductive components of an electrical installation have generally remained the same from a...

Grounding terminology and grounding requirements — is there a reason to...

Quite often Code users ask, “Is there a difference between a grounding conductor and ground grid conductor?”  Or, “Is there a difference between a...

The Case for Advanced High Resistance Grounding

The decision on which grounding system to employ has a direct and quantifiable impact on electrical safety and reliability. As the table below indicates,...

Anatomy of a High Rise

This article will take you through the electrical construction of a nine-story high-rise structure with parking at three floors down and four floors up....